Industrial Crane Scale Instruction Manual Model: BA15S – BA150S BA15SR – BA150SR
- 9 - The BAS Crane Scale is equipped with six Ni-MH 1.2V or two 3.7V internal rechargeable batteries. The battery pack is built in as an integrat
- 10 - The wireless remote control allows controlling the scale and receiving the weighing result on the remote’s LCD display in real time. Key
- 11 - 1. The scale should be properly zeroed before weighing. Proper zeroing is indicated by the Zero Indicator (→0←) on the display. If the d
- 12 - • Parts Counting is used to count parts based on their established average piece weight. • Percent weighing is used to establish the r
- 13 - 1. To begin weighing, press the power button ( ) to turn the scale ON. The scale will go through its initialization procedure and autom
- 14 - 3. Once the stabilization indicator appears on the display, the pan is ready to be tared. To tare the pan, press the “T” button. The display
- 15 - 10.2 Extending the resolution 1. The resolution of the scale can be temporarily increased by pressing the HR key. This temporary increase in
- 16 - All BA Scales are equipped with AZSM, the “Auto Zero Setting Mechanism.” AZSM automatically maintains a center of zero and 5.0d. 1. Ent
- 17 - Functions Options: PCS Off ( PCsoff) Disables Parts Counting PCS On (pcs on) Enables Parts Counting PCS .. (PCS . .) Recalls the last Aver
- 18 - 4. Select “PCS on” by pressing the T key. 5. Available sample size options will alternate on the display. Press the T key to select a size
Table of Contents 1. Cautionary Notes and Precautions…………………………………………………………………………………….………2 1.1. Important Handling Cautions and Warnings……………………….…………
- 19 - 12.2. Using a custom sample size 1. Hang a container or a hanging pan on the hook while in the weighing mode and press the T key to tare.
- 20 - 6. A dashed line will be displayed indicating to manually enter the value for your sample size in the container. To do so, use the following
- 21 - 12.3. Counting based on a known Individual Piece Weight (No Sample Size Required) 1. Hang a container or a hanging pan on the hook and pres
- 22 - 6. A dashed line will be displayed indicating to manually enter the exact individual piece weight of the counted parts. To manually enter the
- 23 - The BA Scales can operate in nine different units of measure: Grams (g), Kilograms (kg), Carats (ct), Pounds (lb), Newton, Grains, Ounces, O
- 24 - Function Options: PER Off ( Peroff) Disables Percent Weighing PER On (per on) Enables Percent Weighing Percent weighing is used to expre
- 25 - 5. Commands “PER OFF” and “PER ON” will be displayed sequentially. To proceed with percent weighing and set the reference sample weight, pres
- 26 - Function Options: Rec Off ( rECoff) Disables Recipe Weighing Rec On (reC on) Enables Recipe Weighing Rec Con (reCCon) allows to continue
- 27 - 5. The display will read 0 indicating that you may place the first ingredient into the pan. Once the Weight of the ingredient stabilized pres
- 28 - 9. The total of all ingredients will be displayed. 10. To continue Recipe making press the MENU select the “Recipe”
- 2 - Remember choose a proper location for you scale. Always handle the unit with care. The correct location and proper environment make an imp
- 29 - Function Options: CAL On ( CaL oN) Starts Quick Calibration. Recommended when calibrating with a single calibration weight. CAL Stp (CALS
- 30 - 4. The scale will perform a tare and the message “LOAD” will be displayed. 5. When the message “LOAD” is displayed, place the cali
- 31 - 16.2 Stepped Calibration (calibrating with multiple calibration weights.) 1. Press the MENU key, when the option “Calib” is displayed press
- 32 - 5. The scale will perform a tare and the message “LOAD” will be displayed indicating to place all calibration weights on the pan. After plac
- 33 - After a weighing transaction is completed, a result data receipt can be printed. To initiate printing, press the data transfer key. Data may
- 34 - Example: To set 1000g in weight B1.5 (d=0.5g) type: S L 1 0 0 0 . 0 CR LF (53h 4Ch 31h 30h 30h 30h 2Eh 30h 0Dh 0Ah). To set 100kg in weigh
- 35 - 17.3 Bites 1. Press the MENU key, when the option “Port - 1” is displayed press the T key, and then select the option “Bites” by press the T
- 36 - A detailed transaction receipt can be printed after weighing has been completed. The receipt can be customized to include the following info
- 37 - 18.1 Enabling and Disabling Receipt Fields 1. Press the MENU key, when the option “Print” is displayed press the T key, and then select a d
- 38 - Function Options: LOC Off ( LOC oFF) Disables the LOC Dynamic Weighing Function LOC On (LOC on) Enables and Starts the LOC Dynamic Weighi
- 3 - CAUTION: • The scale is designed for indoor use only. • Do not operate the scale in hazardous areas or conditions. • Do not use the scale i
- 39 - 20.1 Storing a Tare Value Manually 1. Press the MENU key, when the option “Tare” is displayed press the T key, and then select the option
- 40 - 20.2 Storing a Tare Value Automatically 1. Hang a container or a hanging pan and press the MENU key to enter the main menu. 2.
- 41 - 20.3 Recalling a previously stored tare value. 1. Press the MENU key, when the option “Tare” is displayed press the T key, and then select
- 42 - This function allows you to find the maximum (highest) or minimum (lowest) weight in a series of weights. 1. Press the MENU key, when th
- 43 - This function changes the unit of weight to Newton (N) - 1N ≈0.101971 kg 1. Press the MENU key, when the option “Newton” is displayed pre
- 44 - This function is used when vibration is encountered during weighing. This may be the result of ground vibration, or a vibrating live load o
- 45 - Function Options: Dat On (DAT oN) Enables date and time printing with every weighing result. Dat Off (DAToff) Disables date and time printi
- 46 - 3. Use the following keys to change the current time 4. Once the time has been set the scale will display “PM” or “AM”. Press the
- 47 - 24.3 Enabling PIN access to the Date Configuration Function. Configuration of the current date and time can be protected with a PIN. Once set
- 48 - Threshold check weighing is used to check whether a weight of an object falls within specified threshold limits. Function Options: Thr Off
- 4 - When mounting take extra caution and make sure that your mounting method will support a load which is equal to twice the weight of the sca
- 49 - 4. After setting all limit sets, select “Set-0” in order to return to weighing with the limits enabled. 5. To perform check weighi
- 50 - Function Options: Tot Prn (totPRN) Displays and prints transaction total. (Does not reset the sum value) Tot Off (totoff) Displays and dis
- 51 - 4. Once the weight has been added, remove the object from the weighing pan. 5. Wait for the scale to return to 0 and place
- 52 - In order to use the Crane Scale with the remote control, both the BAS Crane Scale as well as the remote control must be set to the same RF Ch
- 53 - Function Options: AUT OFF (AOF oFF) Disables the Auto OFF Function. Scale is always on. AUT On (aOF on) Enables the Auto Off Function. Scal
- 54 - The function “lb bal” is used to configure the unit to weigh in grams (g) or pounds (lb). “Lb Bal” optimize the scale’s accuracy and resolu
- 55 - The Active function is used to customize the scale’s Main Menu. This feature should be used to deactivate functions or features that are not
- 56 - Error or Indicator Cause Explanation / Solution - - - - Below zero Re-zero the scale by pressing the Æ0Å key. - - Taring is not allowed
- 57 - PURCHASER’S 12-MONTH WARRANTY Warranty is valid only if the attached warranty registration card is completed and returned within 30 days.
Fulcrum Inc. 100 Delawanna Ave.,#120 Clifton, NJ 07014 (973) 473 6900 (973) 777 8302 http://www.fulcruminc.net
- 5 - 2.1 Scale Specifications Model BA15S BA15SR BA30S BA30SR BA60S BA60SR BA150S BA150SR Capacity 15 kg / 30 lbs 30 kg / 60 lbs 60 kg / 150
- 6 - Key Primary Function Power On and Power Off ÆTÅ Tare – used to tare the weighing pan Æ0Å Zero – used to zero the scale (Legal for Trade m
- 7 - Front View Front View w/Remote Control Side View Rear View Remote Control RS232 Port and Opto-Isolator Output Cha
- 8 - 1. Carefully remove the crane scale, ac adapter, as well as the remote control and antenna (optional) out of the packaging. 2. After rem
Comments to this Manuals